3-Series® Processors: Recovery Procedure
Answer ID: 5153 | Access Level: Privileged | Updated: 02/16/2023 02:42 PM
The following procedures will recover a 3-Series® processor in situations where it is unresponsive:
Communications to the Processor Cannot be Established |
- Press the HW-R button.
- Press the SW-R button 5 times with a 1 second gap between presses.
NOTE: Pressing the SW-R button too fast can cause the processor to not start the self-recovery process. Ensure a 1 second gap between each press.
- The processor will now begin the self-recovery process. It may take 30 minutes or longer for the process to fully complete.
- Establish a USB connection from the processor to a computer.
NOTE: For MPC3-XXX devices use Ethernet.
- Open the Text Console tool in the Crestron Toolbox™ software. Check for a prompt in Text Console, it should be the standard prompt.
- Using the Package Update Tool, load the current 3-Series .puf file.
NOTE: The current .puf file can be found on the respective processor's product page in the Resources tab, under the Software & Firmware header.
The device should now be communicating properly. If the issue was not resolved, repeat the procedure above.
NOTE: If the standard prompt did not appear for the processor, contact Crestron's True Blue Techincal Support.